Building Coverage Ratio & Floor Area Ratio Calculator (Japan) | Maximum Building Area and Total Floor Area From Site Area and Zoning (How Many Tsubo Can You Build?), the Floor Area Ratio Limit From the Front Road Width (× 4/10 or 6/10), Setback Area on Roads Narrower Than 4 m (Article 42-2 Roads), Coverage Relief for Corner Lots and Fire Zones, Specified Road Relief and Prorating Sites Across Zones | Charts by Zone, Road Width and Site Size
The Building Coverage Ratio & Floor Area Ratio Calculator answers questions such as “how big a house can I build on this plot?”, “what is my floor area ratio on a 4 m road?”, “how much land do I lose to the setback?” and “what is my coverage ratio on a corner lot?”. Enter the site area (m² or tsubo), the zoning district, the coverage ratio and floor area ratio set by the city plan, and the front road width to get the maximum building area (a guide to the ground floor size) and the maximum total floor area in m² and tsubo. It applies the floor area ratio limit of “road width × 4/10 (residential zones) or 6/10” when the front road is under 12 m, the setback of 2 m from the road centre line on Article 42-2 roads narrower than 4 m (and the case with a river or cliff on the far side), the coverage relief for corner lots and for fire-resistant buildings in fire and quasi-fire zones (no limit for fire zones designated at 80%), and the relief within 70 m of a specified road at least 15 m wide. It also shows the floor area you can build in two or three storeys, and how much basement and garage space can be left out of the floor area ratio. Includes prorating by area (weighted average) for sites that straddle two or more zones, and charts of the ratios for each zoning district, the floor area ratio limit by road width, and what you can build on sites of each size in tsubo.
How big a house can you build on this plot?
Works out the maximum building area and total floor area from the site area, zoning, designated coverage and floor area ratios, and the front road width. Handles the setback on roads under 4 m, corner lot and fire zone relief, and specified road relief.
= 30.25 tsubo
Designated coverage ratio (city plan)
Designated floor area ratio (city plan)
Road width multiplier
If the site faces two or more roads, enter the width of the widest. The standard is 4/10 for residential zones and 6/10 for others; only areas designated by the local authority use a different number.
Corner lot relief
Fire zone / quasi-fire zone relief
Specified road (15 m or wider) relief
Max building area (guide to ground floor size)
60 m²
18.15 tsubo, coverage ratio 60%
Max total floor area (counted in floor area ratio)
160 m²
48.4 tsubo, floor area ratio 160%
| Site area (used in calculation) | 100 m² | 30.25 tsubo |
|---|---|---|
| Coverage ratio | 60% | As designated |
| Floor area ratio from road width | 160% | 4 m × 4/10 × 100 |
| Floor area ratio used | 160% | Set by the road width (smaller than the designated 200%) |
Floor area you can build by number of storeys
Assumes every floor uses the full maximum building area. In practice setback-plane rules, height limits, shadow regulations and the floor plan make it smaller.
1 storeys
60 m²
18.15 tsubo
2 storeys
120 m²
36.3 tsubo
3 storeys
160 m²
48.4 tsubo
Reaches the floor area ratio limit
4 storeys
160 m²
48.4 tsubo
Reaches the floor area ratio limit
Some floor space can be left out of the floor area ratio. A residential basement up to 1/3 of the total floor area (up to 80 m² on this site) and a garage or parking space up to 1/5 (up to 40 m²) are excluded. Each figure assumes it is used on its own.
This is a guide based on the general rules of Japan’s Building Standards Act. Setback-plane rules, absolute height limits, shadow regulations, district plans, building agreements and local ordinances (minimum site area, corner lot conditions and so on) can make what you can actually build smaller. Check with your city’s building guidance office or an architect before buying land or designing.
ABOUT
About Building Coverage Ratio & Floor Area Ratio Calculator (Japan) | Maximum Building Area and Total Floor Area From Site Area and Zoning (How Many Tsubo Can You Build?), the Floor Area Ratio Limit From the Front Road Width (× 4/10 or 6/10), Setback Area on Roads Narrower Than 4 m (Article 42-2 Roads), Coverage Relief for Corner Lots and Fire Zones, Specified Road Relief and Prorating Sites Across Zones | Charts by Zone, Road Width and Site Size
The Building Coverage Ratio & Floor Area Ratio Calculator is a free tool that works out the maximum building area and total floor area in m² and tsubo from the site area, zoning district, designated coverage ratio and floor area ratio, and the front road width. It also handles the floor area ratio limit from the road width, the setback on roads narrower than 4 m, corner lot and fire zone relief, specified road relief and prorating sites that straddle zones.
How to use Building Coverage Ratio & Floor Area Ratio Calculator (Japan) | Maximum Building Area and Total Floor Area From Site Area and Zoning (How Many Tsubo Can You Build?), the Floor Area Ratio Limit From the Front Road Width (× 4/10 or 6/10), Setback Area on Roads Narrower Than 4 m (Article 42-2 Roads), Coverage Relief for Corner Lots and Fire Zones, Specified Road Relief and Prorating Sites Across Zones | Charts by Zone, Road Width and Site Size
- 1On “Calculate what you can build”, enter the site area in m² or tsubo
- 2Choose the zoning district and the coverage ratio and floor area ratio designated by the city plan (you can check them on your city’s zoning map)
- 3Enter the front road width. If it is under 4 m, also enter the length of road frontage and what is on the far side of the road
- 4Choose any corner lot, fire zone or specified road relief that applies, then see the maximum building area, total floor area and floor area by number of storeys
- 5If the site straddles two zoning districts, use “Site across zoning districts” and enter the area and ratios of each part
Great for
- Checking how big a house you can build before buying a plot
- Finding out whether you can use the full designated floor area ratio when the front road is narrow
- Seeing how much land you lose to the setback on a road narrower than 4 m
- Checking what your coverage ratio becomes with corner lot or fire zone relief
- Getting a guide to how much floor area two or three storeys allow before planning the layout
- Working out the coverage and floor area ratios for a site that straddles, say, a commercial and a residential zone
Good to know
- The coverage ratio is building area ÷ site area, and the floor area ratio is total floor area ÷ site area. On a 100 m² site with a 60% coverage ratio and a 200% floor area ratio, you can build up to 60 m² of building area and 200 m² of total floor area.
- If the front road (the widest one if the site faces two or more) is under 12 m wide, the floor area ratio is the smaller of the designated ratio and road width × 4/10 (residential zones) or 6/10 (other zones). In a residential zone a 4 m road gives 160% and a 6 m road 240%; in other zones a 4 m road gives 240% and a 6 m road 360%.
- On an Article 42-2 road narrower than 4 m, the boundary with the road is taken as a line 2 m from the road centre line (or 4 m from the far edge if there is a river, cliff or railway on the far side): this is the setback. A site with 10 m of frontage on a 3 m road loses 0.5 m × 10 m = 5 m² of site area, and the road is counted as 4 m wide for the floor area ratio.
- The coverage ratio goes up by 10% for corner lots designated by the local authority, and by 10% for fire-resistant buildings in fire zones or fire-resistant or quasi-fire-resistant buildings in quasi-fire zones (20% for both). A fire-resistant building in a fire zone in an area designated at 80% has no coverage limit (100%).
- Within 70 m of a specified road at least 15 m wide, if the front road is at least 6 m and under 12 m wide, you can add (12 − road width) × (70 − distance to the specified road) ÷ 70 to the road width when working out the floor area ratio. A 6 m road 35 m away gains 3 m and counts as 9 m, which gives 540% in a 6/10 zone.
- If the site straddles two or more zoning districts, the coverage and floor area ratios are prorated by the area of each part. With 60 m² in a neighbourhood commercial zone (80%, 300%) and 40 m² in a Category 1 residential zone (60%, 200%) on a 6 m road, the whole site has a 72% coverage ratio and a 260% floor area ratio. A residential basement can be left out of the floor area ratio up to 1/3 of the total floor area, and a garage up to 1/5.
Questions this tool answers
Use Building Coverage Ratio & Floor Area Ratio Calculator (Japan) | Maximum Building Area and Total Floor Area From Site Area and Zoning (How Many Tsubo Can You Build?), the Floor Area Ratio Limit From the Front Road Width (× 4/10 or 6/10), Setback Area on Roads Narrower Than 4 m (Article 42-2 Roads), Coverage Relief for Corner Lots and Fire Zones, Specified Road Relief and Prorating Sites Across Zones | Charts by Zone, Road Width and Site Size for searches like these:
- how to calculate building coverage and floor area ratio
- floor area ratio 4m road residential zone
- floor area ratio 6m road calculation
- how to calculate setback area
- article 42-2 road floor area ratio 4m
- corner lot coverage ratio 10 percent
- coverage ratio 80 fire zone fire-resistant 100
- specified road relief formula
- floor area ratio site across two zones prorate
- how big a house on 30 tsubo
FAQ
- What happens to the floor area ratio on a 4 m front road?
- If the front road is under 12 m wide, the limit is the smaller of the designated ratio and the road width × 4/10 (residential zones) or 6/10 (other zones). A 4 m road gives 4 × 0.4 = 160% in a residential zone and 240% elsewhere. In a Category 1 residential zone designated at 200% with a 4 m road, you can only use 160%, so a 100 m² site allows 160 m² (about 48.4 tsubo) of total floor area.
- How do you calculate the setback area?
- On a road narrower than 4 m (an Article 42-2 road), you set back to a line 2 m from the road centre line. The setback depth is 2 m − road width ÷ 2, so 0.5 m for a 3 m road. Multiply it by the length of frontage on the road to get the setback area: 5 m² for 10 m of frontage. This part is not counted in the site area, so the ratios are worked out on what is left. If there is a river or cliff on the far side, you set back to 4 m from the far edge.
- How much does a corner lot add to the coverage ratio?
- A corner lot that meets the conditions set by the local authority (prefecture or city) gets 10% more coverage (60% becomes 70%). A fire-resistant building in a fire zone, or a fire-resistant or quasi-fire-resistant building in a quasi-fire zone, adds another 10% for 80%. The conditions for a corner lot (road widths, the angle, the length of frontage and so on) differ by local rules, so check them.
- How big a house can you build on a 30 tsubo plot?
- With a 60% coverage ratio and a 200% floor area ratio, up to 18 tsubo (about 59.5 m²) of building area and 60 tsubo (about 198.3 m²) of total floor area. But on a 4 m road in a residential zone the floor area ratio drops to 160%, so the total floor area is limited to 48 tsubo. In a Category 1 low-rise exclusive residential zone at 50% and 100%, it is 15 tsubo of building area and 30 tsubo of floor area, which two storeys use up.
- What if the site straddles two zoning districts?
- The coverage and floor area ratios are prorated (weighted) by the area of each part. For example, with 60 m² in a neighbourhood commercial zone (80% coverage, 300% floor area ratio), 40 m² in a Category 1 residential zone (60%, 200%) and a 6 m front road, the building area is 48 + 24 = 72 m² and the floor area is 180 + 80 = 260 m², so the whole site has a 72% coverage ratio and a 260% floor area ratio. The road width limit uses 4/10 or 6/10 for each part according to its zone.
- What is the specified road relief?
- If the site faces a road at least 6 m and under 12 m wide that leads to a road at least 15 m wide (a specified road), and the specified road is within 70 m, you can count the front road as wider when working out the floor area ratio. The extra width is (12 − front road width) × (70 − distance to the specified road) ÷ 70. A 6 m road 35 m away gains 3 m and counts as 9 m, allowing 540% in a 6/10 zone or 360% in a 4/10 zone (up to the designated ratio).
ARTICLES
Guides for Building Coverage Ratio & Floor Area Ratio Calculator (Japan) | Maximum Building Area and Total Floor Area From Site Area and Zoning (How Many Tsubo Can You Build?), the Floor Area Ratio Limit From the Front Road Width (× 4/10 or 6/10), Setback Area on Roads Narrower Than 4 m (Article 42-2 Roads), Coverage Relief for Corner Lots and Fire Zones, Specified Road Relief and Prorating Sites Across Zones | Charts by Zone, Road Width and Site Size
Special Thanks